Valid Exam HFDP Book bring you Fantastic Detailed HFDP Study Plan for ASHRAE Healthcare Facility Design Professionals
Valid Exam HFDP Book bring you Fantastic Detailed HFDP Study Plan for ASHRAE Healthcare Facility Design Professionals
Blog Article
Tags: Exam HFDP Book, Detailed HFDP Study Plan, HFDP Test King, Advanced HFDP Testing Engine, Latest HFDP Exam Bootcamp
To stand in the race and get hold of what you deserve in your career, you must check with all the ASHRAE HFDP Exam Questions that can help you study for the ASHRAE HFDP certification exam and clear it with a brilliant score. You can easily get these ASHRAE HFDP Exam Dumps from ASHRAE that are helping candidates achieve their goals.
PassLeaderVCE's ASHRAE HFDP practice exam software tracks your performance and provides results on the spot about your attempt. In this way, our Healthcare Facility Design Professionals (HFDP) simulation software encourages self-analysis and self-improvement. Questions in the ASHRAE HFDP Practice Test software bear a striking resemblance to those of the real test.
ASHRAE HFDP Exam Questions - Pass Your Exam In One Go
So you rest assured that with the ASHRAE HFDP actual questions you will not only ace the ASHRAE HFDP exam predation but also boost confidence to perform well in the final ASHRAE HFDP test. With the ASHRAE HFDP pdf questions you can experience the type and pattern of the final HFDP exam. In this way, you will be confident on the day of the Healthcare Facility Design Professionals HFDP Exam and solve all the ASHRAE HFDP exam questions. The ASHRAE wants to make the HFDP exam preparation simple and quick. To achieve this objective the ASHRAE is offering the top-notch and top-rated HFDP practice test questions in three user-friendly and compatible formats.
ASHRAE Healthcare Facility Design Professionals Sample Questions (Q109-Q114):
NEW QUESTION # 109
Which of the following is a quench duct associated with?
- A. MRI Room
- B. Medical Gas Storage Room
- C. Operating Room
- D. Emergency Generator Room
Answer: A
NEW QUESTION # 110
In accordance with ASHRAE Standard 170, what is the MINIMUM outdoor air change rate for a patient room in a nursing unit?
- A. 12 ACH
- B. 6 ACH
- C. 4 ACH
- D. 2 ACH
Answer: D
Explanation:
Comprehensive and Detailed Explanation:
Outdoor Air: ASHRAE 170, Table 7.1, specifies 2 ACH outdoor air minimum for patient rooms in nursing units, with a total of 6 ACH (remaining from recirculation).
NEW QUESTION # 111
Airborne Infection Isolation Rooms are designed to:
- A. Protect patients from infection
- B. Be switched from neutral to negative
- C. Protect staff and visitors from infection
- D. Be switched from neutral to positive
Answer: C
NEW QUESTION # 112
The following information refers to the diagram above.
The following information refers to the diagram above:
* The room is an Airborne Infection Isolation Room with a series anteroom.
* The room volume is 960 cubic ft. (27 cubic m).
* The room cooling load is 4,000 Btu/hr sensible only. (Ignore latent loads.) (1172 W)
* The supply air temperature is 55° F (12.8° C), and the room temperature set point is 75° F (23.9° C).
* The toilet exhaust is 100 cfm (47.2 L/s).
* The total room envelope leakage area is 35 sq. in. (22.575 sq. cm), (A_L).
* The anteroom supply air volume is 75 cfm (35 L/s).
* The design pressure difference complies with FGI Guidelines (D_p) (in. water/kPa).
* The room air flow difference (Q_d) is defined by the following:
Q_d = (7p)